Skip to content

Lighting & Emission Testing Equipment

Vehicle headlight tester calibrator | MQB-1B

The MQB-1B calibrates the luminous-intensity, optical-axis deviation and low-beam cutoff-line angle measurements of vehicle headlight testers. It includes a standard light source, laser and horizontal/vertical adjustment mechanisms for manufacturing and maintenance use.

Product Overview

The MQB-1B calibrates vehicle headlight testers, covering luminous intensity, optical-axis deviation and the low-beam light/dark cutoff-line angle. It is intended for headlight tester manufacturers and maintenance departments, including pre-delivery checks and calibration after repairs.

The calibrator includes a standard light source, a laser, a regulated DC power supply and a voltmeter, together with horizontal and vertical angle-adjustment mechanisms. Adjusting the light intensity and beam direction provides the conditions needed to check the headlight tester.

Key Features

Adjustable Light Intensity

The regulated power supply controls the intensity of the standard light source over a range of 5,000–80,000 cd. Calibration personnel can check the headlight tester's intensity readings within this range.

Separate Horizontal and Vertical Adjustment

Horizontal and vertical rotation mechanisms adjust the optical-axis direction, with a range of 3° up and down and 3° left and right. Light intensity and angle can be adjusted separately for the relevant calibration task.

Levelling and Alignment Mechanisms

The instrument includes levelling and alignment mechanisms for positioning the calibrator relative to the instrument under test. The main unit is used with a tripod, allowing the calibration station to be arranged around the equipment positions.

Technical Specifications

Optical and Angular Specifications

ParameterMQB-1B
Luminous intensity range5,000–80,000 cd
Optical-axis deflection3° up/down; 3° left/right
Luminous intensity indication errorWithin ±4%
Luminous intensity repeatability≤1%
Luminous intensity stability≤1.5%/10 min
Light-distribution symmetry≤10%
Optical-axis zero indication errorWithin ±5′
Optical-axis angle indication errorWithin ±5′
Angular mechanism backlash error≤3′
Optical-axis change after re-levelling≤3′

Power and Physical Specifications

ParameterMQB-1B
Power supplyAC 220 V ±22 V, 50 Hz ±1 Hz
Rated power200 W
Ambient temperature−5–40°C
Relative humidity≤90%
Overall dimensions (L × W × H)327 × 252 × 341 mm
Main unit weight20 kg
Tripod weight10 kg

Applications and Operating Conditions

Headlight tester manufacturers can use the MQB-1B for measurement checks before delivery. Maintenance departments can also use it to check instruments after repairs.

Before calibration, position the main unit and tripod to suit the instrument under test, and prepare the levelling, alignment and power supply. Site temperature and humidity should remain within the specified limits. Follow the supplied operating requirements for the calibration procedure.

Frequently Asked Questions

Does the MQB-1B Test Vehicle Headlights Directly?

Its main purpose is to calibrate headlight testers. The headlight tester measures the vehicle's lights, while the MQB-1B provides the light source and angular conditions needed to calibrate that instrument.

Which Measurements Can Be Calibrated?

These include luminous intensity, optical-axis deviation and the low-beam light/dark cutoff-line angle. Each task uses the relevant light-intensity and angle settings.

What Is the Difference Between ±3° and ±5′?

The 3° up/down and left/right values describe the optical-axis deflection range. The ±5′ value is an optical-axis angle indication-error specification. The symbol ′ means arcminute; 1° equals 60′. The two values describe different specifications.

How Much Do the Main Unit and Tripod Weigh?

The main unit weighs 20 kg and the tripod weighs 10 kg.

Contact Us

To discuss an MQB-1B calibrator, provide Cartesy with your headlight tester model, calibration tasks and site conditions so that equipment selection and the installation arrangement can be reviewed.

Request a Quote

Request configuration and pricing for your project.

Share your vehicle type, inspection lane layout, target capacity, and required model configuration for Vehicle headlight tester calibrator | MQB-1B.

Share the project location, vehicle types, inspection scope, applicable standards, target throughput, site conditions and current stage. We will confirm the configuration scope before discussing pricing.