Lighting & Emission Testing Equipment
Diesel Exhaust Gas Analyzer | MQY 900/902/903/201/210/204
The MQY-201 and MQY-210 use partial-flow light-transmission measurement to test diesel exhaust opacity. The 201 supports real-time, free-acceleration and oil-temperature measurements at inspection stations and workshops. The 210 is designed for roadside and non-road mobile machinery checks, with a display, USB wireless communication and a lithium battery.
Product Overview
The MQY-201 and MQY-210 are partial-flow opacity meters for diesel vehicle exhaust. They measure exhaust opacity and provide readings such as the light absorption coefficient K. The two models address station-based and mobile testing needs, with different measurement ranges, communication interfaces and power configurations.
The MQY-201 is suitable for vehicle inspection stations, manufacturers, repair workshops and environmental testing organisations. The MQY-210 is designed for roadside checks and emissions testing of non-road mobile machinery. The functions and specifications below apply to these two models individually.
MQY-201: Station and Workshop Testing
The MQY-201 supports real-time and free-acceleration tests for observing changes in exhaust smoke. It measures oil temperature and provides exhaust-gas temperature readings, allowing relevant temperatures to be viewed alongside opacity measurements.
A large LCD and graphical interface make results accessible at the test station. An RS-232 interface connects to an external computer. The separate control and measurement units can be positioned to suit the inspection bay.
MQY-210: Portable Testing and Wireless Communication
The MQY-210 has a built-in display and lithium battery for work that requires moving the instrument between test locations. Its smoke-chamber pressure function measures exhaust pressure inside the chamber. A hot-swappable USB wireless module provides a wireless communication connection.
The protective optical window can be cleaned. Temperature control of the chamber and optical window reduces the effect of moisture condensation on measurements. The unit measures 416 × 160 × 280 mm and weighs approximately 6.7 kg with the internal battery, providing clear dimensions and weight for transport and site planning.
Optical Protection and Temperature Control
Both models use an air curtain to reduce exhaust contamination of the optical system. The MQY-201 controls the temperature of the measurement chamber, while the MQY-210 controls both the chamber and optical window, helping maintain stable measurement conditions.
Technical Specifications
Smoke Measurement Ranges and Resolution
| Model | Measurement | Range | Resolution |
|---|---|---|---|
| MQY-201 | Opacity N | 0–99.9% | 0.1% |
| MQY-201 | Light absorption coefficient K | 0–16.08 m⁻¹ | 0.01 m⁻¹ |
| MQY-210 | Absorption ratio Ns | 0–99.90% | 0.01% |
| MQY-210 | Light absorption coefficient K | 0–16.08 m⁻¹ | 0.01 m⁻¹ |
The MQY-201 has an absolute indication error of ±2.0 percentage points for opacity N. The MQY-210 has a maximum permissible absolute error of ±2.0 percentage points for absorption ratio Ns. The MQY-210 also provides an absorption ratio N range of 0–98.60%, which is distinct from its Ns range.
The MQY-201 measures oil temperature over 0–200 ℃ and exhaust-gas temperature over 0–150 ℃. Both temperature measurements have a resolution of 1 ℃ and an absolute indication error of ±2 ℃.
Equipment and Operating Conditions
| Parameter | MQY-201 | MQY-210 |
|---|---|---|
| Effective optical path length | 215 mm | 201 mm |
| Equivalent optical path length | 430 mm | 430 mm |
| Power supply | AC 220 V ±22 V, 50 Hz ±1 Hz | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Power | 150 W | 150 W |
| Operating ambient temperature | 0–40 ℃ | −5–50 ℃ |
| Operating ambient pressure | 80–106 kPa | 60–110 kPa |
| Ambient relative humidity | ≤95% | ≤95% |
| Dimensions (L × W × H) | Control unit: 353 × 248 × 210 mm; measurement unit: 525 × 170 × 332 mm | 416 × 160 × 280 mm |
| Weight | Control unit: approx. 5 kg; measurement unit: approx. 6 kg | Approx. 4.8 kg; approx. 6.7 kg with internal battery |
| Communication | RS-232 | USB wireless module |
Frequently Asked Questions
Can the MQY-201 Provide Both Oil Temperature and Engine Speed?
Oil-temperature measurement is included. An optional engine-speed analyzer is needed for engine-speed readings; engine speed is not part of the basic opacity measurement channel.
Can the MQY-201 Print Results on Site?
An optional built-in microprinter can output test results on site. The instrument can also communicate with an external computer through RS-232.
Does the MQY-210 Need an External Display for Calibration?
No. The MQY-210 has its own display and supports standalone calibration. An additional display is not required for metrological verification.
How Long Does the MQY-210 Operate on Its Battery?
At an ambient temperature of 25 ℃, the internal lithium battery provides at least 9 hours of operation. This operating-time specification applies to that temperature condition.
Contact Us
Tell Cartesy about the vehicles or machinery, station-based or mobile testing needs, required measurements and data connections. For enquiries about the MQY-900, 902, 903 or 204, provide the specific model and application so that the corresponding configuration can be discussed.
Related Pages
Request a Quote
Request configuration and pricing for your project.
Share your vehicle type, inspection lane layout, target capacity, and required model configuration for Diesel Exhaust Gas Analyzer | MQY 900/902/903/201/210/204.
Share the project location, vehicle types, inspection scope, applicable standards, target throughput, site conditions and current stage. We will confirm the configuration scope before discussing pricing.